{"product_id":"aten-8-outlet-1u-metered-by-bank-pg6308g-at","title":"Aten 8-Outlet 1U, Metered by bank, PG6308G-AT","description":"\u003cp class=\"nx-lead\"\u003eATEN 32A 8-Outlet 1U Met \u0026amp; Switch eco. PDU types: Switched, Rack capacity: 1U, Product colour: Black. AC outlets quantity: 8 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 60309. Cable length: 3 m. Monitoring: Current, Voltage. Nominal input voltage: 100 - 240 V, Maximum current: 32 A, AC input frequency: 50-60 Hz\u003c\/p\u003e\n\u003cp\u003eWhen maintaining operating uptime in a data center or server room, sustainable energy efficiency can make all the difference. The implementation of effective power management often involves improvements at both the hardware and software level. ATEN is introducing its latest PG series of PDUs, available in IEC socket configuration, that are designed with 1U rack housing to accommodate the increasing demand for power to high-density IT equipment in server rooms and data centers. Each PG6308 PDU, utilizing an ARM-Cortex A8 processor, is equipped with 8 port outlets that can power up all connected equipment in less than 10 seconds once plugged in, and delivers the most accurate kWh energy usage data (+\/-1%) for better power consumption habits, baselines, and initiative tracking. With energy saving in mind, the PG6308 is purposed to enable lower energy consumption for best practice in a network infrastructure, while promoting up to 35.04 kw equivalent of power consumption of reduced CO2 emission, reduced electricity expenses, and lower carbon taxes to pay each year.\u0026lt;br\u0026gt;\u0026lt;br\u0026gt;\u0026lt;b\u0026gt;Real-time Alerts via LCD Display\u0026lt;\/b\u0026gt;\u0026lt;br\u0026gt;Once connected to an AC power source, the Home screen displays basic PDU readings, including A (Aggregate Current), V (Voltage), W (Power), and kWh (Power Consumption).\u0026lt;br\u0026gt;\u0026lt;br\u0026gt;The LCD screen lights up red when a Critical, Alert (triggered when a PDU value exceeds a predefined threshold), or Warning (when a value approaches the alert threshold) event is logged.\u0026lt;br\u0026gt;\u0026lt;br\u0026gt;\u0026lt;b\u0026gt;Environment Sensors\u0026lt;\/b\u0026gt;\u0026lt;br\u0026gt;The Sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 environment sensors (i.e. EA1640, sold separately) for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats.\u0026lt;br\u0026gt;\u0026lt;br\u0026gt;\u0026lt;b\u0026gt;Communicate through RS-232 Protocol\u0026lt;\/b\u0026gt;\u0026lt;br\u0026gt;For quick and flexible operation, connecting a serial device to the PDU with its COM port provides another means to undertake communication via CLI commands.\u0026lt;br\u0026gt;\u0026lt;br\u0026gt;\u0026lt;b\u0026gt;Networkable via WiFi\u0026lt;\/b\u0026gt;\u0026lt;br\u0026gt;The PG8308 can be networked via connection to a USB WiFi dongle to perform DCIM, firmware upgrade, log export, quick configuration, and more.\u0026lt;br\u0026gt;\u0026lt;br\u0026gt;\u0026lt;b\u0026gt;Dual LAN Ports for Scalable Network Setup\u0026lt;\/b\u0026gt;\u0026lt;br\u0026gt;The PG8308 is equipped with dual LAN ports (Internet and Intranet) supporting up to 1G Ethernet connection, and can be cascaded to connect up to 64 PDUs, saving expense on installing extra network switches to incorporate network connections while sparing more rack space to accommodate more IT equipment in an expandable network.\u0026lt;br\u0026gt;\u0026lt;br\u0026gt;\u0026lt;b\u0026gt;DCIM Monitoring\u0026lt;\/b\u0026gt;\u0026lt;br\u0026gt;Integrated with ATEN’s eco DC – a PC- and web-based tool for optimized Data Center Infrastructure Management (DCIM) – power distribution, energy, and environmental data from PDUs and connected devices can be monitored via a friendly web GUI for smart power management.\u0026lt;br\u0026gt;\u0026lt;br\u0026gt;\u0026lt;b\u0026gt;Applications\u0026lt;\/b\u0026gt;\u0026lt;br\u0026gt;The PG series intelligent PDUs are perfectly suited to server rack installation requiring energy-efficient power distribution to high-density IT equipment in server rooms or data centers.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual 1G Ethernet ports support cascading up to 64 PDUs\u003c\/li\u003e\n\u003cli\u003eEnvironment sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 ATEN EA1640 environment sensors for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats (sold separately)\u003c\/li\u003e\n\u003cli\u003ePrecise kWh metering (+\/-1% ) for better power consumption habits, baselines, and initiative tracking\u003c\/li\u003e\n\u003cli\u003eWith an ARM Cortex-A8 processor, these PDUs provide advanced control options through USB, COM, environmental sensors, and dual Gigabit LAN ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"nx-spec\"\u003e\n\u003ctr class=\"nx-spec__group\"\u003e\u003cth colspan=\"2\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePDU types\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack capacity\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"nx-spec__group\"\u003e\u003cth colspan=\"2\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlets quantity\u003c\/td\u003e\n\u003ctd\u003e8 AC outlet(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower plug\u003c\/td\u003e\n\u003ctd\u003eIEC 60309\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlet types\u003c\/td\u003e\n\u003ctd\u003eC13 coupler, C19 coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet LAN (RJ-45) ports\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB ports quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"nx-spec__group\"\u003e\u003cth colspan=\"2\"\u003eFeatures\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset button\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"nx-spec__group\"\u003e\u003cth colspan=\"2\"\u003eManagement features\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eCurrent, Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"nx-spec__group\"\u003e\u003cth colspan=\"2\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal input voltage\u003c\/td\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input frequency\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad capacity\u003c\/td\u003e\n\u003ctd\u003e7680 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"nx-spec__group\"\u003e\u003cth colspan=\"2\"\u003eCertificates\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"nx-spec__group\"\u003e\u003cth colspan=\"2\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-20 - 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"nx-spec__group\"\u003e\u003cth colspan=\"2\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e432.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.09 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"nx-spec__group\"\u003e\u003cth colspan=\"2\"\u003eLogistics data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eTaiwan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eGenuine, authentic product.\u003c\/strong\u003e Supplied by NexaCore. Sourced through European distribution. Price excludes VAT — VAT is added at checkout (0% for VAT-registered EU businesses under reverse charge).\u003c\/p\u003e","brand":"Aten","offers":[{"title":"Default Title","offer_id":59642258063692,"sku":"W129130397","price":602.78,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1090\/7336\/7372\/files\/Img_36486286.jpg?v=1793361266","url":"https:\/\/nexakft.com\/products\/aten-8-outlet-1u-metered-by-bank-pg6308g-at","provider":"NexaCore","version":"1.0","type":"link"}